Which Janitza UMG 96RM universal meter do you choose!?

The UMG 96 series by Janitza consists of seven universal meters with unique characteristics. The meters all digitally display the three measured phases. Through various communication protocols, it is possible to request the information decentrally.

A meter for every application

The universal meters have various different properties so that there is a meter for every application. The basis of every meter is the UMG 96RM.

 

View Janitza UMG 96RM series Ask your questions

Universal meter UMG 96RM series - Janitza

Janitza UMG 96RM universal gauge per model

Universal Energy Meter UMG 96RM        
Type E CBM P PN EL M -
Janitza UMG 96RM voorkant Janitza UMG 96RM-e Janitza UMG 96RM-cbm Janitza UMG 96RM-p Janitza UMG 96RM-pn Janitza UMG 96RM-el Janitza UMG 96RM-m Janitza UMG 96RM achterkant
General specifications        
Clock/memory 256 Mb 256 Mb 256 Mb - - - -
Mounting type Panel 96 Panel 96 Panel 96 Panel 96 Panel 96 Panel 96 Panel 96
Integrated logic - - - - - - -
 
Power Quality        
Harmonic analysis 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD
Dips, peaks and transients - - - - - - -
Flicker - - - - - - -
Safety measurement (RCM) v - - v - - -
IEC61000-4-30 - - - - - - -
Reports EN50160/61000-2-4 - - - - - - -
Exactitude V/A(%) 0,2 0,2 0,2 0,2 0,2 0,2 0,2
Exactitude kWh 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s
 
Interfaces en protocols        
RS232/RS485 (Modbus) -/v -/v -/v -/v -/v -/v -/v
Ethernet v - - 2x v - 2x
USB - v v - - - -
Profibus DP - - v - - - -
M-bus - - - - - v -
PROFINET - - - v - - -
BACnet IP Option - - - - - -
 
Inputs and outputs        
Digital in-/outputs 3/2 4/- 4/- 3/2 -/- -/2 -/2
Analog in-/outputs 2/- -/- -/- 2/- -/- -/- -/-
Voltage / current channels 4/4 4/4 4/4 4/3 4/3 4/3 4/3
 
Auxiliary voltage and article numbers        
90...277Vac/90...250Vdc JA101912 JA100792 JA101910 JA100085 JA100290  JA101911 JA101905
24...90Vac/24...90Vdc JA100104 JA100126 JA100133 JA100134 JA100106  JA100105 JA100101

 

Universal meter - Janitza UMG 96RM

Characteristics:

  • Multifunctional power analyzer
  • Modbus RTU communication (via RS485)
  • Measure to the 40th harmonic
  • THD-U / THD-I
  • 2 Digital outputs
  • Online measurement values

 

View universal meter - Janitza UMG 96RM

Universal meter UMG 96RM - Janitza
Universal meter UMG 96RM-P Profibus - Janitza

Janitza UMG 96RM-P - Profibus

Characteristics:

  • Profibus communication (instead of Modbus RTU)
  • USB communication
  • Internal memory of 256MB in which historical measured values ​​can be saved
  • 4th flow measurement input
  • 6 digital outputs, 4 digital inputs View Janitza UMG 96RM-P

 

View universal meter - Janitza UMG 96RM-P

Janitza UMG 96RM-M - M-Bus Universal Meter

Characteristics:

  • M-Bus communication (instead of Modbus RTU)

 

View universal meter - Janitza UMG 96RM-M

Universal meter UMG 96RM-M M-bus - Janitza
Universal energy meter - UMG 96RM-E Ethernet - Janitza

Janitza UMG 96RM-E - Ethernet universal meter

Characteristics UMG 96RM-E:

  • Ethernet connection (Modbus TCP / IP)
  • Modbus gateway (modbus master)
  • Internal web server
  • Internal memory of 256MB in which historical measured values can be saved
  • 4th flow measurement input
  • RCM measurement
  • 5 digital outputs or 2 digital outputs and 3 digital inputs
  • 2 temperature inputs
  • Detection of short interruptions (> 200msec)

 

View universal meter - Janitza UMG 96RM-E

Janitza UMG 96RM-EL - Ethernet light version

Characteristics UMG 96RM-EL Ethernet Light:

  • Modbus TCP over IP communication (instead of Modbus RTU over RS485)

 

View universal meter - Janitza UMG 96RM-EL

Universal energy meter - UMG 96RM-EL Ethernet light-versie - Janitza
Universal energy meter - UMG 96RM-PN PROFINET - Janitza

Janitza UMG 96RM-PN - PROFINET universal meter

Characteristics UMG 96RM-PN PROFINET :

  • 5 digital outputs or 2 digital outputs and 3 digital inputs
  • 2 temperature inputs

 

View universal meter - Janitza UMG 96RM-PN

Janitza UMG 96RM-CBM - Clock Battery Memory

Characteristics UMG 96RM-CBM - Clock Battery Memory:

  • Internal memory of 256MB in which historical measured values ​​can be saved
  • 4th flow measurement input
  • 6 digital outputs, 4 digital inputs

 

View universal meter - Janitza UMG 96RM-CBM

Universal Energy Meter - UMG 96RM-CBM Clock Battery Memory - Janitza

close-video-button