Universal meters from Janitza are available as panel mounting and DIN rail version and can be equipped with various communication protocols. Depending on the type, the meters are provided with sufficient memory to store measurement profiles.

Determine the right load

The modern measuring technology and the high sample rate also accurately measure the power of electronic loads such as frequency converters, LED lighting and charging facilities. This way there are no 'holes' in the consumption measurement and the correct load is determined. The UMG 96RM series is suitable for panel mounting while the UMG 103-CBM is suitable for DIN rail mounting.

Interfacing

Depending on the model, the Janitza Universal Meters are delivered with different bus protocols. Modbus RTU over RS485, Modbus over TCP over IP, Profibus, Profinet, Bacnet IP, M-Bus, making it possible to integrate into almost all overhead systems.

 

View universal meters in the webshop Ask your questions

Universal energy meters UMG 96PA and UMG 103-CBM - Janitza
Universal energy meters - Power management - Janitza

Features Universal meters

Application area

The Janitza universal energy meters are often used to measure outgoing fields in low-voltage main distributors, in sub-distributors or in bus-bar terminal boxes.

Features UMG 96-RM universal meter:

  • 4 quadrant measurements in IT, TN, and TT networks
  • 4 voltage and 4 current measurement inputs
  • 2 measurement inputs for differential current measurement
  • Measurement according to IEC61000-4-30
  • Scan speed: 20kHz
  • JASIC graphical programming functions
  • Analysis of harmonic pollution up to 40th order

Features UMG 103-CBM universal meter:

  • 4 quadrant measurement
  • Suitable for 4 leader systems
  • 3 voltage and 4 current measurement inputs
  • 2 measurement inputs for differential current measurement
  • Measurement according to IEC61000-4-30
  • Scan speed:> 20kHz
  • JASIC graphical programming functions
  • Analysis of harmonic pollution up to 40th order

Overview of standard universal energy meters

Meter group         Universal energy meters
Type UMG 96-PA Expansion module Expansion module UMG 96-S2 UMG 103 CBM
  Janitza UMG 96RM-cbm Janitza UMG 96RM-e Janitza UMG 96RM-e Janitza UMG 96RM-pn Janitza UMG 103-CBM
General specifications        
Clock/Memory 4 MB - - - 4 MB
Mounting type Panel 96 - - Panel 96 DIN rail
Integrated logic - - - - -
 
Power Quality        
Harmonic analysis 1..25 + THD - - 1..15 + THD 1..25 + THD
Dips, peaks and transients - - - - -
Flicker - - - - -
Safety measurement(RCM) Option v v - -
IEC61000-4-30 - - - - -
Reports EN50160/61000-2-4 - - - - -
Exactitude V/A(%) 0,2 - - 0,2 0,2
Exactitude kWh 0,5s - - 0,5s 0,5s
 
Interfaces and protocols        
RS485 (Modbus) v - - v v
Ethernet - v - - -
USB - - - v -
Profibus DP - - - v -
M-bus - - - - -
PROFINET - - - - -
BACnet IP - - - - -
 
Inputs and outputs        
Digital in-/outputs 3/3 - - - -/-
Analog in-/outputs Option/1 3/- 3/- -/- -/-
Voltage / current channels 4/3 -/1 -/1 4/4 4/3
 
Auxiliary voltage and article numbers        
90..277Vac/90..250Vdc JA100284 JA900119 JA900117 JA100312 JA500138
24..90Vac/24..90Vdc JA100304 - - - -

 

Overview special universal energy meters

Universal Energy Meter UMG 96RM        
Type E CBM P PN EL M -
Janitza UMG 96RM voorkant Janitza UMG 96RM-e Janitza UMG 96RM-cbm Janitza UMG 96RM-p Janitza UMG 96RM-pn Janitza UMG 96RM-el Janitza UMG 96RM-m Janitza UMG 96RM achterkant
General specifications        
Clock/memory 256 Mb 256 Mb 256 Mb - - - -
Mounting type Panel 96 Panel 96 Panel 96 Panel 96 Panel 96 Panel 96 Panel 96
Integrated logic - - - - - - -
 
Power Quality        
Harmonic analysis 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD 1..40 + THD
Dips, peaks and transients - - - - - - -
Flicker - - - - - - -
Safety measurement (RCM) v - - v - - -
IEC61000-4-30 - - - - - - -
Reports EN50160/61000-2-4 - - - - - - -
Exactitude V/A(%) 0,2 0,2 0,2 0,2 0,2 0,2 0,2
Exactitude kWh 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s
 
Interfaces en protocols        
RS232/RS485 (Modbus) -/v -/v -/v -/v -/v -/v -/v
Ethernet v - - 2x v - 2x
USB - v v - - - -
Profibus DP - - v - - - -
M-bus - - - - - v -
PROFINET - - - v - - -
BACnet IP Option - - - - - -
 
Inputs and outputs        
Digital in-/outputs 3/2 4/- 4/- 3/2 -/- -/2 -/2
Analog in-/outputs 2/- -/- -/- 2/- -/- -/- -/-
Voltage / current channels 4/4 4/4 4/4 4/3 4/3 4/3 4/3
 
Auxiliary voltage and article numbers        
90...277Vac/90...250Vdc JA101912 JA100792 JA101910 JA100085 JA100290  JA101911 JA101905
24...90Vac/24...90Vdc JA100104 JA100126 JA100133 JA100134 JA100106  JA100105 JA100101

 

Universal meter UMG 103-CBM

The universal meter UMG 103-CBM from Janitza is a multifunction meter for DIN rail mounting. Universal meters have an RS485 interface with a Modbus RTU protocol, enabling extremely cost-effective networking. The UMG 103 series of universal meters is insensitive to EMC interference.

Features UMG 103-CBM universal meter:

  • Multifunction meter for DIN rail mounting
  • Modbus RTU communication (via RS485)
  • Measure until the 25th harmonic
  • THD-U / THD-I
  • Online measurement values

 

View UMG 103-CBM and read more specifications

Universal meters UMG 103-CBM - Janitza